Impact of gaseous phase presence in liquid on orifice flowmeter measurement error

Authors

  • Elżbieta Wróblewska Wrocław University of Science and Technology image/svg+xml , Wydział Mechaniczno-Energetyczny , Katedra Techniki Cieplnej Author https://orcid.org/0000-0002-6486-6722
  • Piotr K. Synowiec Wrocław University of Science and Technology image/svg+xml , Wydział Mechaniczno-Energetyczny , Katedra Techniki Cieplnej Author
  • Wiesław Wędrychowicz Wrocław University of Science and Technology image/svg+xml , Wydział Mechaniczno-Energetyczny , Katedra Techniki Cieplnej Author

DOI:

https://doi.org/10.36119/15.2025.9.4

Keywords:

flow rate, two-phase flow, measurement uncertainty, orifice plate flow meter

Abstract

Orifice flow meters are among the most widely used devices in industrial measurements. Their popularity stems primarily from their versatility across various fluid flows, high accuracy, and broad measurement range. However, these devices demand strict installation conditions to ensure accurate measurements, which can be challenging, if not difficult, to meet in industrial environments. Measurements conducted on the research stand for two-phase water-air flow allowed for the estimation of discrepancies between flow rates determined by a reference electromagnetic flow meter (measuring water volumetric flow) and an orifice flow meter (measuring two-phase volumetric flow). The observable decrease in the pressure drop (Δp) indication at the ISA orifice plate with flange taps suggests the presence of errors in volumetric flow rate determination during two-phase flow measurements. Furthermore, the presence of an additional phase increases measurement uncertainty, leading to acquired data being subject to significant errors

Downloads

Download data is not yet available.

References

Piotr Synowiec, Wiesław Wędrychowicz, Artur Andruszkiewicz; Pomiary strumieni przepływów dwufazowych metodami ultradźwiękowymi za kolanem rurociągu; Elektronika (Warszawa). 2016. R. 57, nr 9, s. 115-117, DOI: 10.15199/13.2016.9.27

Piotr Synowiec, Artur Andruszkiewicz, Wiesław Wędrychowicz, Paweł Regucki; Badania możliwości pomiaru strumienia objętości czynnika dwufazowego przepływomierzem ultradźwiękowym; Przegląd Elektrotechniczny. 2015. R. 91, nr 10, s. 179-182, DOI: 10.15199/48.2015.10.37

Hanyu Wang, Shuichiro Miwa, Wen Zhou, Takashi Hibiki, Koji Okamoto, Development of an industry-applicable two-phase flow regime identification approach using flow-induced vibration acceleration signals, Engineering Applications of Artificial Intelligence, Volume 154, 2025, 110751, ISSN 0952-1976, https://doi.org/10.1016/j.engappai.2025.110751.

Downloads

Published

2025-09-30

How to Cite

Wróblewska, E., Synowiec, P., & Wędrychowicz, W. (2025). Impact of gaseous phase presence in liquid on orifice flowmeter measurement error. Instal, 9, 39-42. https://doi.org/10.36119/15.2025.9.4

Most read articles by the same author(s)