Influence of pipe bedding on their structural integrity
DOI:
https://doi.org/10.36119/15.2023.2.7Keywords:
pipes, load capacity, structural integrity, bedding coefficientAbstract
The method of calculating the load capacity of pipes recommended in the ATV guidelines is given. It is approximate. Then, the proposed exact method of calculations is given. The recommendations for determining the bedding coefficient, which have a very significant impact on the load capacity of pipes after their installation, have been reviewed. There are three examples of different pipe beddings indicating the consequences of more unfavorable and more favorable pipe beddings in relation to the recommended beddings.
Downloads
References
Arbeitsblatt ATV-DVWK – A 127: Statische Berechnung von Abwasserkanälen und –leitungen, 3 Auflage, 2000.
Błaszczyk W., Roman M., Stamatello H.: Kanalizacja t.1., Arkady, Warszawa, 1974.
Centrum Techniki Komunalnej: Instrukcja projektowania i budowy przewodów kanalizacyjnych z rur Wipro, Warszaw, 1978.
Kuliczkowska E., Parka A.: The structural integrity of corroded concrete sewers, Engineering Failure Analysis, 2019,104,409-421. DOI: 10.1016/j.engfailanal.2016.04.026
Downloads
Published
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors retain copyright and grant the journal the right of first publication, with the work simultaneously licensed under a Creative Commons Attribution 4.0 International License, which permits others to share the work with appropriate acknowledgment of the authorship and initial publication in this journal.